GASESUnit: ppmNDIR (Non-Dispersive Infrared)

CO2 (CO₂)

Carbon Dioxide

Primary indicator of indoor ventilation adequacy, metabolic buildup, and occupant cognitive performance.

SAFE EXPOSURE THRESHOLD
< 1,000 ppm
ASHRAE Standard 62.1 (Indoor Ventilation Standard)
Primary SourceGlobal baseline atmospheric concentration (~420 ppm)
Key Health RiskFatigue, lethargy, drowsiness, and sluggish cognitive processing
SCIENTIFIC BACKGROUND

What is CO2 (Carbon Dioxide)?

Carbon Dioxide (CO₂) is a naturally occurring gas emitted continuously by human exhalation. In enclosed rooms with insufficient fresh air ventilation, CO₂ levels escalate rapidly. Elevated indoor CO₂ directly impairs cognitive decision-making, induces drowsiness, triggers headaches, and signals poor dilution of airborne viral aerosols.

Indoor Sources
  • •Human and occupant metabolic respiration in occupied rooms
  • •Open combustion from gas cooking stovetops and heaters
  • •Insufficient outdoor fresh air exchange in tightly sealed buildings
Outdoor Sources
  • •Global baseline atmospheric concentration (~420 ppm)
  • •Fossil fuel combustion from dense urban traffic and power stations
PHYSIOLOGICAL IMPACT

Health Effects of CO2

Short-Term Exposure
  • •Fatigue, lethargy, drowsiness, and sluggish cognitive processing
  • •Significant drop in executive decision-making scores and strategic thinking
  • •Throat dryness, frontal headaches, and reduced meeting productivity
Long-Term & Chronic Risks
  • •Persistent indoor discomfort and chronic occupational fatigue
  • •Increased risk of viral transmission in high-occupancy spaces due to stale air stagnation
EXPOSURE THRESHOLDS

Concentration Levels & Safety Guidelines

Standardized thresholds to identify when active ventilation and air filtration intervention is required.

Optimal (Fresh Air)
400 – 700 ppm

Optimal indoor air quality with strong ventilation and maximum cognitive performance.

Acceptable
700 – 1000 ppm

Standard compliant indoor environment with good ventilation exchange rates.

Drowsiness & Reduced Focus
1000 – 1500 ppm

Complaints of stale air and noticeable decline in occupant attention spans.

Severe Cognitive Impairment
> 1500 ppm

Headaches, sluggishness, and severe concentration loss; immediate fresh air cycle needed.

International Health & Regulatory Standards (CO2)
OrganizationGuideline LimitExposure Timeframe
ASHRAE Standard 62.1< 1,000 ppmIndoor Ventilation Standard
WELL Building Standard< 800 ppmEnhanced Air Quality Feature
OSHA5,000 ppm8-Hour Time-Weighted Average Limit
DETECTION ENGINEERING

How DLE Measures CO2

Dual-Beam Non-Dispersive Infrared (NDIR) Optical Sensor

Infrared light is passed through an absorption gas chamber tuned to the 4.26 µm CO₂ absorption band. The optical attenuation directly computes exact molecular gas concentration with zero chemical cross-sensitivity.

Dual-channel optical reference eliminating long-term thermal drift
Lifetime calibration stability exceeding 10 years
Immune to humidity swings and background VOC gases
Related DLE Hardware & Solutions
Intelligent Environmental MonitorsAir Quality Monitors

NDIR CO₂ monitoring with automated Demand-Controlled Ventilation (DCV) integration.

Explore System
HVAC Energy OptimizationEnergy Management

Modulate outdoor air dampers based on real-time CO₂ occupancy to eliminate energy waste.

Explore System