The Sensible combines comprehensive multi-pollutant sensing with an interactive touch display interface. Designed for direct occupant engagement in executive suites, conference facilities, and educational institutions, it transforms complex air quality telemetry into accessible, actionable insights.

Measured Channels
11 Parameters
Primary Protocol
Wi-Fi
Cloud Sync
Active Real-Time
sensible product visual
SENSIBLE
ENGINEERING HIGHLIGHTS

Engineered for continuous telemetry & high reliability.

The Sensible architecture integrates discrete optical, chemical, and physical sensor elements with low-latency edge buffering for dependable operational performance.

Full-color high-resolution capacitive touch display
Comprehensive 10+ parameter environmental and chemical array
On-device historical charting and trend visualization
Local internal data retention with cloud failover
Rechargeable battery for roaming facility inspections
Direct Wi-Fi synchronization to DLE web dashboard
STANDARDS & CREDENTIALS

Engineered for Global Environmental Standards

Our environmental telemetry hardware is designed to simplify building compliance audits, ESG reporting, and automated HVAC integration.

Calibrated Baseline
Green Building

LEED v4.1 Compliant

Meets EQ Credit criteria for Enhanced Indoor Air Quality strategies & continuous particulate tracking.

Air Concept

WELL v2 Certified Ready

Aligned with Air Feature A01, A05, and A08 for multi-parameter real-time telemetry verification.

Ventilation Standard

ASHRAE 62.1 Compatible

Optimized for Demand-Controlled Ventilation (DCV) closed-loop HVAC actuation via BACnet & Modbus.

Continuous Monitoring

RESET Air Grade Ready

Hardware calibrated for accredited indoor air quality data feeds with cloud payload verification.

TELEMETRY CHANNELS

Monitored Environmental & Gas Parameters (11)

Real-time measurement channels active on the Sensible baseline architecture.

PM1.0particulate

Ultra-fine particulate matter with diameter less than 1.0 µm

Unit: µg/m³Optical / Laser Scattering
PM2.5particulate

Fine inhalable particles with diameters 2.5 µm and smaller

Unit: µg/m³Optical / Laser Scattering
PM10particulate

Inhalable coarse particles with diameters 10 µm and smaller

Unit: µg/m³Optical / Laser Scattering
CO2gases

Carbon Dioxide concentration indicating ventilation efficacy

Unit: ppmNDIR
COgases

Carbon Monoxide poisonous gas from incomplete combustion

Unit: ppmElectrochemical
O3gases

Ozone photochemical oxidant and respiratory irritant

Unit: ppmElectrochemical / Metal Oxide
TVOCvocs

Total Volatile Organic Compounds off-gassing from building materials

Unit: mg/m³ / ppbPID
HCHOvocs

Formaldehyde chemical vapor common in adhesives and furniture

Unit: mg/m³ / ppmElectrochemical
Temperatureenvironmental

Ambient dry-bulb thermal measurement

Unit: °CSolid-state Bandgap
Humidityenvironmental

Relative air moisture saturation percentage

Unit: % RHCapacitive Polymer
AQIderived

Standardized Air Quality Index computed from multiple criteria pollutants

Unit: Index (0-500)Algorithmic Aggregation
SENSING PHYSICS

Sensor Technology Principles

Educational overview of physical and optical sensing methodologies deployed across this platform.

Optical / Laser Scattering

Uses focused laser light scattering to detect discrete particle diameters and compute mass concentration per unit volume in real time.

NDIR (Non-Dispersive Infrared)

Measures gas absorption at specific infrared wavelengths for high-stability, drift-resistant carbon dioxide and methane quantification.

Electrochemical Sensing

Quantifies target gas molecules through chemical oxidation or reduction at an electrode, yielding high sensitivity in parts-per-billion and parts-per-million ranges.

Photoionization Detection (PID)

Emits high-energy ultraviolet light to ionize volatile organic gas molecules, delivering broad-spectrum detection of volatile organic compounds.

Solid-State Environmental Sensing

Integrated semiconductor and capacitive sensors for high-accuracy thermal, relative humidity, pressure, and ambient illuminance data.

INTEGRATION ARCHITECTURE

Connectivity & Software Topology

Edge Data Transport

Supported physical and wireless interfaces

Wi-FiStandard Interface
BluetoothStandard Interface
USB-CStandard Interface
Encrypted TLS 1.3 edge-to-cloud transport architecture.

Software Platform Compatibility

Integrated digital control layers

Mobile AccessiOS & Android App
Web DashboardMulti-Site Web Portal
Cloud SyncDLE Cloud Telemetry
Enterprise APIREST & MQTT Streams
Fail-Safe Buffer: Non-volatile local flash99.9% Telemetry Target
TELEMETRY & CLOUD ECOSYSTEMv2.4 Ready

Real-time monitoring across web, mobile & facility displays.

Every sensor stream is instantly ingested into the DLE Cloud Platform, offering multi-tenant analytics, historical heatmaps, and zero-latency TV lobby displays.

dle-cloud.internal / telemetry / station-node-04
Live Edge Stream (0.5s)
Real-Time AQIGood Quality
28US AQI Standard
PM2.5
6.4 µg/m³
CO₂ Level
462 ppm
TVOC
0.08 mg/m³
Relative Humidity
48.2 %

24-Hour Particulate Concentration Trend

Continuous 1-minute averaged telemetry buffer

PM2.5 PM10
00:0006:0012:0018:00Now
REST API & MQTT Export
Automated PDF Compliance
Modbus & BACnet Gateway
SYSTEM ARCHITECTUREDLE Air Intelligence

Connecting physical sensing to autonomous optimization.

Every DLE monitoring device integrates directly into the DLE Air Intelligence platform, transforming raw telemetry into energy-efficient ventilation control and predictive facility health.

Sense

Transducer Ingestion

Optical laser scattering and dual-channel NDIR ambient sampling.

Connect

Edge Transport

Encrypted payload routing via RS-485 Modbus, Wi-Fi, 4G, and MQTT.

Understand

Contextual Analytics

Spatial heatmaps, dynamic baselines, and thermal load analysis.

Optimize

Closed-Loop Control

Demand-Controlled Ventilation (DCV) actuation and automated BMS control.

Platform Endpoints: iOS / Android Apps Multi-Site Web Portal REST / MQTT APIs
Continuous Telemetry Engine
APPLICATIONS & USE CASES

Target Operating Environments

Executive Boardrooms & Collaborative Spaces

Validated compatibility and optimized telemetry profiles for this environment.

Residential Living Environments

Validated compatibility and optimized telemetry profiles for this environment.

Healthcare Consulting Rooms

Validated compatibility and optimized telemetry profiles for this environment.

Educational Laboratories

Validated compatibility and optimized telemetry profiles for this environment.

Commercial Building Environmental Audits

Validated compatibility and optimized telemetry profiles for this environment.

ENGINEERING SPECIFICATIONS

Technical Data & Parameters

DLE maintains rigorous testing standards. Field metrics marked To be confirmed represent pending factory certification test results and will update automatically upon commercial release.
Technical SpecificationSpecification Value / Engineering Architecture
Measured ParametersAQI, PM1, PM2.5, PM10, CO, CO2, TVOC, HCHO, O3, Temp, RH
Display InterfaceFull-color High-definition Touchscreen
Sensing SuiteLaser Scattering, NDIR, Electrochemical, MOS
Measurement RangesTo be confirmed
Local Data LoggingIntegrated Flash Storage
Wireless InterfacesWi-Fi (802.11 b/g/n), Bluetooth
Power SourceInternal Rechargeable Lithium Battery / USB-C Power
Operating Time on BatteryTo be confirmed
DimensionsTo be confirmed
WeightTo be confirmed
DOCUMENTATION

Datasheets & Technical Literature

datasheet

Sensible Station Datasheet

Pending upload
brochure

Interactive Environmental Intelligence Series

Pending upload
manual

User Manual & UI Navigation Guide

Pending upload
TECHNICAL FAQ

Frequently Asked Questions

The interactive UI is designed to toggle between comprehensive technical parameter dashboards and high-level ambient summary views suitable for public visibility.
EXPLORE ALTERNATIVES

Related Monitoring Systems

Ready to evaluate Sensible for your facility?

Submit your project parameters and our solutions team will provide architectural integration guidance and commercial quote estimates.