Dual Life Energy
DUAL LIFE ENERGY
Click to enter directly
portableVentilation IntelligenceIntegrated Telemetry

Pocket CO2

Engineered to evaluate ventilation sufficiency and occupant density in enclosed environments, the Pocket CO2 combines precision NDIR optical absorption sensing with mobile-first telemetry. It enables facility managers, educators, and occupants to identify stagnant air accumulation and verify fresh air exchange rates in real time.

Measured Channels
3 Parameters
Primary Protocol
Wi-Fi 802.11 b/g/n
Cloud Sync
Active Real-Time
pocket-co2 product visual
POCKET CO2
ENGINEERING HIGHLIGHTS

Engineered for continuous telemetry & high reliability.

The Pocket CO2 architecture integrates discrete optical, chemical, and physical sensor elements with low-latency edge buffering for dependable operational performance.

Drift-resistant optical NDIR carbon dioxide sensing
Integrated temperature and relative humidity telemetry
Immediate visual air turnover alerts
Wi-Fi connectivity for multi-room logging
Portable form factor with internal rechargeable cell
Continuous synchronization with DLE Air Intelligence platform
STANDARDS & CREDENTIALS

Engineered for Global Environmental Standards

Our environmental telemetry hardware is designed to simplify building compliance audits, ESG reporting, and automated HVAC integration.

Calibrated Baseline
Green Building

LEED v4.1 Compliant

Meets EQ Credit criteria for Enhanced Indoor Air Quality strategies & continuous particulate tracking.

Air Concept

WELL v2 Certified Ready

Aligned with Air Feature A01, A05, and A08 for multi-parameter real-time telemetry verification.

Ventilation Standard

ASHRAE 62.1 Compatible

Optimized for Demand-Controlled Ventilation (DCV) closed-loop HVAC actuation via BACnet & Modbus.

Continuous Monitoring

RESET Air Grade Ready

Hardware calibrated for accredited indoor air quality data feeds with cloud payload verification.

TELEMETRY CHANNELS

Monitored Environmental & Gas Parameters (3)

Real-time measurement channels active on the Pocket CO2 baseline architecture.

CO2gases

Carbon Dioxide concentration indicating ventilation efficacy

Unit: ppmNDIR
Temperatureenvironmental

Ambient dry-bulb thermal measurement

Unit: °CSolid-state Bandgap
Humidityenvironmental

Relative air moisture saturation percentage

Unit: % RHCapacitive Polymer
SENSING PHYSICS

Sensor Technology Principles

Educational overview of physical and optical sensing methodologies deployed across this platform.

NDIR (Non-Dispersive Infrared)

Measures gas absorption at specific infrared wavelengths for high-stability, drift-resistant carbon dioxide and methane quantification.

Solid-State Environmental Sensing

Integrated semiconductor and capacitive sensors for high-accuracy thermal, relative humidity, pressure, and ambient illuminance data.

INTEGRATION ARCHITECTURE

Connectivity & Software Topology

Edge Data Transport

Supported physical and wireless interfaces

Wi-Fi 802.11 b/g/nStandard Interface
USB-CStandard Interface
Encrypted TLS 1.3 edge-to-cloud transport architecture.

Software Platform Compatibility

Integrated digital control layers

Mobile AccessiOS & Android App
Web DashboardMulti-Site Web Portal
Cloud SyncDLE Cloud Telemetry
Enterprise APICustom Integration
Fail-Safe Buffer: Non-volatile local flash99.9% Telemetry Target
TELEMETRY & CLOUD ECOSYSTEMv2.4 Ready

Real-time monitoring across web, mobile & facility displays.

Every sensor stream is instantly ingested into the DLE Cloud Platform, offering multi-tenant analytics, historical heatmaps, and zero-latency TV lobby displays.

dle-cloud.internal / telemetry / station-node-04
Live Edge Stream (0.5s)
Real-Time AQIGood Quality
28US AQI Standard
PM2.5
6.4 µg/m³
CO₂ Level
462 ppm
TVOC
0.08 mg/m³
Relative Humidity
48.2 %

24-Hour Particulate Concentration Trend

Continuous 1-minute averaged telemetry buffer

PM2.5 PM10
00:0006:0012:0018:00Now
REST API & MQTT Export
Automated PDF Compliance
Modbus & BACnet Gateway
SYSTEM ARCHITECTUREDLE Air Intelligence

Connecting physical sensing to autonomous optimization.

Every DLE monitoring device integrates directly into the DLE Air Intelligence platform, transforming raw telemetry into energy-efficient ventilation control and predictive facility health.

Sense

Transducer Ingestion

Optical laser scattering and dual-channel NDIR ambient sampling.

Connect

Edge Transport

Encrypted payload routing via RS-485 Modbus, Wi-Fi, 4G, and MQTT.

Understand

Contextual Analytics

Spatial heatmaps, dynamic baselines, and thermal load analysis.

Optimize

Closed-Loop Control

Demand-Controlled Ventilation (DCV) actuation and automated BMS control.

Platform Endpoints: iOS / Android Apps Multi-Site Web Portal REST / MQTT APIs
Continuous Telemetry Engine
APPLICATIONS & USE CASES

Target Operating Environments

Classrooms & Lecture Halls

Validated compatibility and optimized telemetry profiles for this environment.

Conference Rooms & Co-working Spaces

Validated compatibility and optimized telemetry profiles for this environment.

Residential Air Quality Verification

Validated compatibility and optimized telemetry profiles for this environment.

Commercial Building Ventilation Audits

Validated compatibility and optimized telemetry profiles for this environment.

Healthcare Waiting Areas

Validated compatibility and optimized telemetry profiles for this environment.

ENGINEERING SPECIFICATIONS

Technical Data & Parameters

DLE maintains rigorous testing standards. Field metrics marked To be confirmed represent pending factory certification test results and will update automatically upon commercial release.
Technical SpecificationSpecification Value / Engineering Architecture
Target ParametersCarbon Dioxide (CO2), Temperature, Relative Humidity
CO2 Sensor PrincipleNon-Dispersive Infrared (NDIR)
CO2 Measurement RangeTo be confirmed
CO2 AccuracyTo be confirmed
Sampling IntervalTo be confirmed
Display InterfaceHigh-contrast Digital Screen
ConnectivityWi-Fi 2.4 GHz
Power SourceInternal Rechargeable Battery
Battery Operating HoursTo be confirmed
Charging PortUSB Type-C
Dimensions & WeightTo be confirmed
Calibration MethodAutomatic Baseline Calibration (ABC) / Manual
DOCUMENTATION

Datasheets & Technical Literature

datasheet

Pocket CO2 Technical Datasheet

Pending upload
brochure

Indoor Ventilation Monitoring Overview

Pending upload
manual

User & Calibration Guide

Pending upload
TECHNICAL FAQ

Frequently Asked Questions

NDIR (Non-Dispersive Infrared) sensors measure the specific infrared light absorption of carbon dioxide molecules, offering superior accuracy, selectivity, and long-term calibration stability compared to estimated chemical sensors.
EXPLORE ALTERNATIVES

Related Monitoring Systems

Pocket PM

Pocket PM

View Product

Ready to evaluate Pocket CO2 for your facility?

Submit your project parameters and our solutions team will provide architectural integration guidance and commercial quote estimates.

MONITORSPURIFIERSSOLUTIONS